Description
Description
The HUUM chimney set for through the ceiling installations takes the flue straight up from the top of a HUUM wood burning sauna heater, through the ceiling and out above the roof. Compatible with all HUUM wood burning heaters, the set includes everything the vertical run needs: two 1 m double-wall chimney sections, a welded chimney base, a double-wall cover plate for sloped ceilings, a roof rafter attachment, a roof penetration for inclinations of 0–20 degrees, a rain collar and a chimney cap. The heater and sauna stones are sold separately, and HUUM requires the stove and flue to be installed by a chimney specialist.
Features
Technical Specification
| Specification | |
| Installation type | Through the ceiling (vertical flue) |
| Compatibility | All HUUM wood burning sauna heaters |
| Roof penetration | Suits roof inclinations of 0–20 degrees |
Included in the chimney set
- Double-wall chimney (2 × 1 m sections)
- Chimney base, welded
- Cover plate for penetration of sloped ceiling, double wall
- Roof rafter attachment to the chimney
- Roof penetration (inclination 0–20 degrees)
- Rain collar
- Chimney cap
Connecting the stove to the chimney
The sauna stove must be connected to the chimney by a specialist. The flue gas outlet is on the top of the stove.
The stove is connected to the chimney with special flue pipes, which may be caulked with heat-resistant sealing rope where necessary. Curves in the connection elbows must be smooth to minimise draught loss, and the pipe is inserted through the wall of the chimney and sealed with mineral wool. The flue gases must be directed into a separate flue; it is forbidden to use a common flue shared with other furnaces.
As specified by HUUM, forced extract ventilation might cause problems with the air exchange of the room and the sufficiency of combustion air for the furnace; designing and constructing such ventilation systems is permitted only on the sole responsibility of a licensed specialist.
Installation
The HUUM sauna stove and flue must be installed by a chimney specialist. A technical drawing is available under the Downloadable Files tab on this page.
Brand
HUUM combines age-old sauna knowledge, smart technology and modern Nordic design; its DROP heater won the Red Dot Award for Product Design in 2015, and HUUM heaters are UKCA certified.
Ordering
If you are unsure this part fits your heater, contact support@finnmarksauna.com with your heater model before ordering.
Delivery & Returns
Delivery
We offer fast and reliable delivery to customers across the UK and beyond. For full details on shipping times and costs, please review our delivery policy.
Returns
We offer hassle-free returns within 30 days of purchase, so you can shop with complete confidence. For details, see our returns policy.
Warranty & Quality Promise
We are committed to delivering products of the highest quality, for details surrounding warranty please contact us.
Description
The HUUM chimney set for through the ceiling installations takes the flue straight up from the top of a HUUM wood burning sauna heater, through the ceiling and out above the roof. Compatible with all HUUM wood burning heaters, the set includes everything the vertical run needs: two 1 m double-wall chimney sections, a welded chimney base, a double-wall cover plate for sloped ceilings, a roof rafter attachment, a roof penetration for inclinations of 0–20 degrees, a rain collar and a chimney cap. The heater and sauna stones are sold separately, and HUUM requires the stove and flue to be installed by a chimney specialist.
Features
| Specification | |
| Installation type | Through the ceiling (vertical flue) |
| Compatibility | All HUUM wood burning sauna heaters |
| Roof penetration | Suits roof inclinations of 0–20 degrees |
Included in the chimney set
- Double-wall chimney (2 × 1 m sections)
- Chimney base, welded
- Cover plate for penetration of sloped ceiling, double wall
- Roof rafter attachment to the chimney
- Roof penetration (inclination 0–20 degrees)
- Rain collar
- Chimney cap
Connecting the stove to the chimney
The sauna stove must be connected to the chimney by a specialist. The flue gas outlet is on the top of the stove.
The stove is connected to the chimney with special flue pipes, which may be caulked with heat-resistant sealing rope where necessary. Curves in the connection elbows must be smooth to minimise draught loss, and the pipe is inserted through the wall of the chimney and sealed with mineral wool. The flue gases must be directed into a separate flue; it is forbidden to use a common flue shared with other furnaces.
As specified by HUUM, forced extract ventilation might cause problems with the air exchange of the room and the sufficiency of combustion air for the furnace; designing and constructing such ventilation systems is permitted only on the sole responsibility of a licensed specialist.
Installation
The HUUM sauna stove and flue must be installed by a chimney specialist. A technical drawing is available under the Downloadable Files tab on this page.
Brand
HUUM combines age-old sauna knowledge, smart technology and modern Nordic design; its DROP heater won the Red Dot Award for Product Design in 2015, and HUUM heaters are UKCA certified.
Ordering
If you are unsure this part fits your heater, contact support@finnmarksauna.com with your heater model before ordering.
Delivery
We offer fast and reliable delivery to customers across the UK and beyond. For full details on shipping times and costs, please review our delivery policy.
Returns
We offer hassle-free returns within 30 days of purchase, so you can shop with complete confidence. For details, see our returns policy.
Warranty & Quality Promise
We are committed to delivering products of the highest quality, for details surrounding warranty please contact us.